3.4.5 Report 0x05 – Cancel Command
This command cancels the current command.
Table 3-5 - Usage Table for Report 0x05
Bit
7
6
5
4
3
2
1
0
Byte 0
0x05
Byte 1
0
3.4.6 Report 0x06 – Request User Selection
This command causes the device to prompt the user to select the transaction type (debit, credit, etc.) or to
verify the transaction amount, as shown below:
Figure 3-4 - DynaPro Mini "Amount OK" User Selection Screen
An error will be reported in ACKSTS of Report 0x01 – Response ACK in the following cases:
Bad parameter (0x82)
System is not available (0x8A)
If transaction amount is required, no amount has been sent (0x8B)
If no error occurs, when the command completes (selection made, user cancelled, or timeout), the device
will do the following:
1) Clear the display
2) Return to the idle state
3) Send Report 0x25 – User Selection Response Report to the host
Table 3-6 - Usage Table for Report 0x06
Bit
7
6
5
4
3
2
1
0
Byte 0
0x06
Byte 1
Wait Time in seconds, (1 – 255; 0 = 256 seconds)
Byte 2
Message ID:
0 = Transaction type Credit / Debit
1 = Verify Transaction Amount
2 = Transaction type Credit / Other / Debit
3 = Transaction type Credit / EBT / Debit
4 = Transaction type Credit / Gift/ Debit
5 = Transaction type EBT / Gift / Other
Byte 3
Mask Key: