Set the baud rate to match the other serial communications equipment on the

serial link. Normally, the baud rate is set to the highest value that all the serial

equipment is capable of transmitting and receiving.

23





BAUD RATE





ABBREVIATED PRINTING

Select



for full print or Command T transmissions (meter address,

parameter data and mnemonics) or



for abbreviated print transmissions

(parameter data only). This will affect all the parameters selected in the print

options. (If the meter address is 0, it will not be sent during a full transmission.)







- Enters the sub-menu to select the meter parameters to appear during a

print request. For each parameter in the sub-menu, select



for that parameter

information to be sent during a print request or



for that parameter information

not to be sent. A print request is sometimes referred to as a block print because

more than one parameter information (meter address, parameter data and

mnemonics) can be sent to a printer or computer as a block.

PARAMETER

DESCRIPTION

FACTORY MNEMONIC

 

Counter A



CTA

 

Counter B



CTB

 

Counter C



CTC



Rate



RTE



Max. & Min.



MIN MAX



A B C Scale Factors



SFA SFB SFC



A B C Count Load



LDA LDB LDC



1 2 3 4 Setpoints *



SP1 SP2 SP3 SP4

*Setpoints are plug-in card dependent.



DATA BIT

Select either 7 or 8 bit data word lengths. Set the word length to match the

other serial communications equipment on the serial link.





PARITY BIT

Set the parity bit to match that of the other serial communications equipment

on the serial link. The meter ignores the parity when receiving data and sets the

parity bit for outgoing data. If no parity is selected with 7 bit word length, an

additional stop bit is used to force the frame size to 10 bits.





METER ADDRESS

Enter the serial meter (node) address. The address range is dependent on the



parameter. With a single unit, configured for RLC protocol (



=



), an address is not needed and a value of zero can be used. With multiple

units (RS485 applications), a unique 2 digit address number must be assigned

to each meter.

Data Bit

Parity Bit

Meter

Address

Transmit

Delay

bAUd

Baud

Rate

tYPE

Comms

Type

PAR

7-SrL

dAtA

Addr

dELAY

Abbreviated

Printing

AbrV

OPt

Pro

PAr

HILO

C CNt

b CNt

PAR

rAtE

CNtLd

SCFAC

SPNt

Print

Setpoint

Values

Print

Count

Loads

Print

Scale

Factors

Print

Max/Min

Print

Rate

Print

Counter C

Print

Counter B

A CNt

Print

Counter A

YES

NO

Print

Options

PARAMETER MENU











to



- Modbus

to



- RLC Protocol

6.7 mOdule 7 - s

erial

C

OmmuniCaTiOns

p

arameTers

(



)

paXi O

nly

Module 7 is the programming module for the Serial Communications

Parameters. These parameters are used to match the serial settings of the PAXI

with those of the host computer or other serial device, such as a terminal or

printer. This programming module can only be accessed if an RS232 or RS485

Serial Communications card is installed.

This section also includes an explanation of the commands and formatting

required for communicating with the PAXI. In order to establish serial

communications, the user must have host software that can send and receive

ASCII characters or Modbus protocol. Red Lion’s Crimson software can be

used for configuring the PAXI (See Ordering Information). For serial hardware

and wiring details, refer to the bulletin shipped with the plug-in card.

This section does NOT apply to the DeviceNet or Profibus-DP communication

cards. For details on the operation of the Fieldbus cards, refer to the bulletin

shipped with each card.

u

- Modbus RTU



- Modbus ASCII



- RLC Protocol (ASCII)

Select the desired communications protocol. Modbus protocol provides

access to all meter values and parameters. Since Modbus is included within the

PAXI, the PAX Modbus option card, PAXCDC4, should not be used. The

PAXCDC1 (RS485), or PAXCDC2 (RS232) card should be used instead.

COMMUNICATIONS TYPE

u







TRANSMIT DELAY

Following a transmit value (‘*’ terminator) or Modbus command, the PAXI

will wait this minimum amount of time before issuing a serial response.



to



seconds

Parameters below only appear when Communications Type parameter

(



) is set to



.