Page 16: Arameters

background image

16

16

6.3 mOdule 3 - d

isplay

and

p

rOgram

l

OCK

-

OuT

p

arameTers

(



)

3-LOC

COdE

Lock-out

Rate Display

Factor x

Access

Scale

Count Load

Access

Counter x

Display

Lock-out

Counter x

Pro

Lock-out

Min Display

Lock-out

Max Display

Access

Setpoint 1-4

Security

Code

LO

HI

SP-n

CNt

PAR

rAtE

CNtLd

SCFAC

x

x

x

d-LEV

Display

Intensity

Access

PARAMETER MENU

x = Counter A , Counter B, and then Counter C

n = Setpoints 1 to 4

Module 3 is the programming for Display lock-out and “Full” and “Quick”

Program lock-out.

When in the Display Mode, the available displays can be read consecutively

by repeatedly pressing the

DSP key. An annunciator indicates the display being

shown. These displays can be locked from being visible. It is recommended that

the display be set to



when the corresponding function is not used.

“Full” Programming Mode permits all parameters to be viewed and

modified. This Programming Mode can be locked with a security code and/or

user input. When locked and the

PAR key is pressed, the meter enters a Quick

Programming Mode. In this mode, setpoint, count load, scale factor values, and

the Display Intensity Level () parameter can still be read and/or changed

per the selections below.



 

COUNTER A B C DISPLAY LOCK-OUT

RATE DISPLAY LOCK-OUT

MAX. MIN. DISPLAY LOCK-OUT

These displays can be programmed for



or



.



 



 













to



The Count Load Values can be programmed for



,



, or



.

The setpoint displays can be programmed for



,



, or



(See the

following table). Accessible only with the Setpoint Plug-in card installed.





COUNT LOAD A B C ACCESS LOCK-OUT









The Scale Factor values can be programmed for



,



, or



.





SCALE FACTOR A B C ACCESS LOCK-OUT





Entry of a non-zero value will cause the prompt



to appear when trying to

access the “Full” Programming Mode. Access will only be allowed after entering

a matching security code or universal code of



. With this lock-out, a user input

would not have to be configured for Program Lock-out. However, this lock-out is

overridden by an inactive user input configured for Program Lock-out.

SECURITY CODE











SETPOINT 1 to 4 ACCESS LOCK-OUT













PROGRAMMING MODE ACCESS

SECURITY

CODE

USER INPUT

CONFIGURED

USER INPUT

STATE

WHEN PAR KEY IS

PRESSED

“FULL” PROGRAMMING MODE ACCESS

0

not



————

“Full” Programming

Immediate access.

>0

not



————

Quick Programming

After Quick Programming with correct code # at



prompt.

>0



Active

Quick Programming

After Quick Programming with correct code # at



prompt.

>0



Not Active

“Full” Programming

Immediate access.

0



Active

Quick Programming

No access

0



Not Active

“Full” Programming

Immediate access.

Throughout this document, Programming Mode (without Quick in front) always refers to “Full” Programming (all meter parameters are accessible).

Shaded areas represent program access that is model dependent.

Shaded areas are model dependent.

Not visible in Display Mode



Visible in Display Mode



DESCRIPTION

SELECTION

Not visible in Quick Programming Mode

Visible and changeable in Quick Programming Mode

Visible but not changeable in Quick Programming Mode

DESCRIPTION

SELECTION







The Display Intensity Level can be programmed for



,



, or



.

DISPLAY INTENSITY ACCESS LOCK-OUT



