Important Safety Instructions

Personal Safety

WARNING: Personal Injury

 This equipment weighs approximately 98 lbs (44.5 kg). Use safe lifting

techniques when lifting this equipment as prescribed by the Occupational
Safety and Health Association (OSHA) or other local codes.

 Use standard safety equipment such as safety glasses, ear protection, steel-

toed safety boots, safety hard hats, etc. as prescribed by the Occupational
Safety and Health Association (or other local codes) when working on this
equipment.

 Use standard safety practices when working with electrical equipment

(e.g., remove all jewelry, use insulated tools, wear cotton clothing, etc.)

 Never work alone when installing or servicing this equipment. Have

someone nearby that can come to your aid if necessary.

FLEXpower ONE System Safety

WARNING: Lethal Voltage

 Review the system configuration to identify all possible sources of energy.

Ensure ALL sources of power are disconnected before performing any
installation or maintenance on this equipment. Confirm that the terminals
are de-energized using a validated voltmeter (rated for a minimum
1000 Vac and 1000 Vdc) to verify the de-energized condition.

 Do not perform any servicing other than that specified in the installation

instructions unless qualified to do so or as instructed to do so by OutBack
Power Systems Technical Support personnel.

WARNING: Burn Hazard

Internal parts can become hot during operation. Do not remove the cover
during operation or touch any internal parts. Be sure to allow them sufficient
time to cool down before attempting to perform any maintenance.

WARNING: Fire Hazard

 In residential installations: check for multi-wire branch circuit wiring at the

location for the installation. A possible fire hazard can exist if 120 Vac only
sources (such as inverters and generators) are wired incorrectly into
120/240 Vac panels containing multi-wire branch circuits. Consult the local
electric code for assistance.

 Do not place combustible or flammable materials within 12 feet (3.7 m) of

the equipment.

 Use only the recommended cable sizes (or greater) for AC and DC

conductors in compliance with local codes. Ensure all conductors and
connections are in good condition. Do not operate the unit with damaged
or substandard cabling.