Specifications

Weather Monitor II

Page 43

S

PECIFICATIONS

Inside Temperature

Range: -5˚ to 140˚ F (-20˚ to 60˚ C)
Accuracy: ± 1˚F (± 0.5˚C)

Outside Temperature

Range: -50˚ to 140˚ F (-45˚ to 60˚ C)

Accuracy: ±

1˚F (

±

0.5˚C)

Wind Direction

Display Resolution: 16 points (22.5˚) on compass rose, 1˚ in digital display

Accuracy: ±

Wind Speed

Large Wind Cups
Range: 2 to 150 mph, 3 to 241 km/h, 2 to 130 knots, 1 to 67 m/s

Accuracy: ± 2 mph, 3 km/h, 2 knots, 1 m/s or ±

5%, whichever is greater

Small Wind Cups
Range: 3 to 175 mph, 5 to 282 km/h, 3 to 150 knots, 1 to 67 m/s

Accuracy: ± 2 mph, 3 km/h, 2 knots, 1 m/s or ±

5%, whichever is greater

Wind Chill

Range: -134˚ to 98˚F (-92˚ to 37˚C)

Accuracy: ±

2˚F (

±

1˚C)

Rainfall

Daily Range: 0 to 40.95”(0 to 819 mm)
Accumulated Range: 0 to 99.99”(0 to 9999 mm)
Accuracy:

±(4% + 1 count) for rates from 0.01” to 2” (0.2 mm to 50 mm) per hr;

±(5% + 1 count) for rates from 2” to 4” (50 mm to 100 mm) per hr

Barometric Pressure

Range: 26.00 to 32.00"; 660.0 to 810.0 mm; 880.0 to 1080.0 hPa
Accuracy:

±

0.05";

±

1.3 mm;

±

1.7 hPa

Inside Humidity

Range: 10 to 90% RH

Accuracy: ±

3%

Outside Humidity

Range: 0 to 100% RH

Accuracy: ±

3% (1 to 90% RH),

±

4% (90 to 100% RH)

Time

Accuracy:

±

15 sec/month