Using the Console Functions

Page 32

Weather Monitor II

3. Press ALARM twice to display the low alarm setting.

4. Use ENTER to set the alarm to 40˚F (see “Using the Enter Key” on page 16 for instruc-

tions).

L

OW

O

UTSIDE

T

EMPERATURE

A

LARM

(E

XAMPLE

)

5. Press TEMP to exit.

The alarm is now set and will sound when the outside temperature drops below
40˚F.

To Set the Barometric Trend Alarm

1. Press BAR.

2. Press UNITS to select the desired unit of measure.

3. Press ALARM.

4. Press ENTER and hold it down.

The display will cycle through the possible entries: 0.02, 0.04, and 0.06 inches
(0.5, 1.0 and 1.5 mm or 0.7, 1.4 or 2.0 mb). The entry represents a change in baro-
metric pressure over the course of approximately one hour. Therefore, setting the
alarm to 0.04 inches means that the alarm will sound if the barometric pressure
changes (rises or falls) by 0.04 inches (1 mm or 1.4 mb) in any hour long period.
This alarm is checked approximately every 15 minutes.

B

AROMETRIC

T

REND

A

LARM

5. Release ENTER when the desired setting is on the display.

6. Press any key to exit.

Note:

The barometric trend alarm does not discriminate between rising and falling barometric pres-
sure—check the barometric trend arrow to determine if barometric pressure rose or fell.

To Silence an Alarm

Press CLEAR. The high pitched beeping sound stops, though the alarm is not
cleared. The word ALARM and the function triggering the alarm remains on
the display until alarm conditions are no longer met or the alarm is cleared.