Highs and lows, Condition, High – DAVIS Health EnviroMonitor: Console User Manual
Page 51: Time, Autoclear, Additional, Information, Direction of gust, Alarms, Alarm
Health EnviroMonitor Overview
Page 12
Health EnviroMonitor Manual
H
IGHS
AND
L
OWS
The Health EM records highs and lows for many weather conditions. All highs
and lows represent the maximum or minimum reading since the last time you
cleared each individual high/low register. If you have enabled AutoClear for a
particular high/low (see “Enabling/Disabling AutoClear” on page 46), this
reading will represent the high/low since the time of the AutoClear. In other
words, it will track highs and lows over a 24 hour period. If you do not use
AutoClear, you may track daily, weekly, monthly, or yearly values, depending
on how often you clear the high/low. For all highs and lows the time at which
they occurred is stored along with the value.
The table below summarizes the highs and lows stored by the Health EM.
A
LARMS
The Health EM features a set of alarms which can be programmed to sound
whenever a reading exceeds a particular value. With the exception of baromet-
ric pressure, dew-point, and time, all alarms sound when a reading reaches the
alarm threshold and will continue to sound until the reading returns to within
the threshold. This means that for all high alarms, the alarm sounds when a
reading reaches the alarm threshold continues to sound until the reading drops
below the alarm threshold. On all low alarms, the alarm sounds when a read-
ing reaches the alarm threshold and continues to sound until the reading rises
above the alarm threshold.
The table below summarizes the Health EM’s alarms.
C
ONDITION
H
IGH
L
OW
T
IME
A
UTO
C
LEAR
A
DDITIONAL
I
NFORMATION
Outside T-H Index
Yes
Yes
Yes
Outside T-H-S-W Index
Yes
Yes
Yes
Inside T-H Index
Yes
Yes
Yes
UV Radiation Intensity
Yes
Yes
Yes
Wind Chill
Yes
Yes
Yes
Outside Temperature
Yes
Yes
Yes
Yes
Inside Temperature
Yes
Yes
Yes
Yes
Wind Speed
Yes
Yes
Yes
Direction of Gust
Solar Radiation
Yes
Yes
Yes
Rate of Rainfall
Yes
Yes
Yes
Outside Humidity
Yes
Yes
Yes
Yes
Inside Humidity
Yes
Yes
Yes
Yes
C
ONDITION
H
IGH
A
LARM
L
OW
A
LARM
S
PECIAL
A
LARM
Outside T-H Index
Yes