Use enter to set the alarm to 32˚f, Low outside temperature alarm threshold (32˚f), Press temp to save and exit – DAVIS Health EnviroMonitor: Console User Manual
Page 36: Setting the barometric pressure alarm, Press and hold down enter, Release enter when the desired setting appears, Barometric pressure alarm (1.5 mm per hour), Press bar to save and exit, Setting the dew-point alarm
Using the Health EM
Page 44
Health EnviroMonitor Manual
4. Use ENTER to set the alarm to 32˚F.
L
OW
O
UTSIDE
T
EMPERATURE
A
LARM
T
HRESHOLD
(32˚F)
5. Press TEMP to save and exit.
The alarm is now set and will sound when the outside temperature drops to
32˚F.
Setting the Barometric Pressure Alarm
This section describes the barometric pressure alarm. The barometric pressure
alarm is a special alarm in that it is triggered when the rate of change in the
barometric pressure equals or exceeds the alarm threshold. There are three pos-
sible barometric pressure alarm thresholds: 0.02”, 0.04”, or 0.06” (0.5 mm,
1.0 mm, 1.5 mm or 0.7 hPA, 1.4 hPA, 2.0 hPA). The alarm is triggered whether
the barometric pressure rises or falls. To determine which way the barometric
pressure is moving, check the barometric trend arrow.
1. Press BAR to display the current barometric pressure.
2. Press ALARM to display the barometric pressure alarm threshold.
3. Press and hold down ENTER.
The unit will cycle through the available alarm thresholds in a continuous
loop as long as you hold down ENTER.
4. Release ENTER when the desired setting appears.
B
AROMETRIC
P
RESSURE
A
LARM
(1.5
MM
P
ER
H
OUR
)
5. Press BAR to save and exit.
The alarm is now set and will sound when the rate of change in the baromet-
ric pressure equals or exceeds the alarm threshold.
Setting the Dew-Point Alarm
This section describes the dew-point alarm. The dew-point alarm is a special
alarm in that it is triggered when the temperature comes within 2˚F of the dew-
point.
1. Press HUM as necessary to display the current dew-point.
2. Press ALARM to display the dew-point alarm threshold.