Changing a Setting

Step

Action

1

Use the UP or DOWN ARROW keys to select the item you want
to change. The item is selected when a black filled rectangular
box surrounds the entire line.

2

Press the EDIT key and then use the UP or DOWN ARROW keys
to change the number or setting.

3

Once you have changed a setting press the ACCEPT key. Press
the EXIT key once you have made all the settings.

Logging Device

If you are using a GPS receiver with the PF3000 you must use a memory
card to save the instantaneous GPS data.

If you...

Select

Do not have a GPS receiver.

NONE

Do have a GPS receiver.

MEMORY CARD

Logging Interval

This setting determines how often the GPS information is saved to the
memory card. It also affects how large an area each GPS record will
represent on a map and how many logging hours are available before the
memory card becomes full.

There are three possible settings for the logging interval. 1, 2 or 3 seconds

.

The recommended setting is either two or three seconds.

Distance Traveled (ft)

1 sec

2 sec

3 sec

3 mph

4.4

8.8

13.2

5 mph

7.3

14.6

21.9

Approximate Logging Hours Until Card is Full

1 sec

2 sec

3 sec

20 M SANDISK ATA
Flash Card

25.8

47.2

65.2

32 M SANDISK ATA
Flash Card

41.2

75.5

104.3

NOTE: The logging hours available can vary from the numbers shown
above due to a variety of operating conditions. The number of fields
and loads, the number of separate files on the card and the number of
times the memory is copied to the card all affect the log file size.