PF 3000 Cotton Yield Monitor

System Wiring

Ag Leader Technology

March 2002

7-4

System Wiring

Refer to the last page to see a table of the pin-outs of the picker cables for
the PF3000.

Pin-Out of Port 1

Pin

Signal

1

Regulated 5 volts (limit current draw to 50 ma)

2

RS-232 Transmit (from monitor)

3

RS-232 Receive (into monitor)

4

12 Volt Power (switched, reverse polarity

protected, limit current draw to 1
amp) The PF3000 must be ON for
current to flow.

5

RS-232 Ground

6

Ground

7

Second RS-232 Transmit (not in use)

8

Second RS-232 Receive (not in use)

9

Auxiliary A/D Input (keep input voltage between

ground and 5 volts)