General Operation
Light Bar
Ag Leader Technology
Skip with No
Headlands
Use this pattern when the equipment being used to work a field
requires a larger turning radius than the standard parallel A-B pattern
allows. Skip enables the operator to specify the number of swaths to
skip between passes and provides racetrack guidance across the field
accordingly.
Pattern: Set to Skip Pass.
Headland Pattern: Set to None.
IMPORTANT: In order for this pattern to function
properly the Lightbar pass number must be displayed on
the screen of the PF monitor.
NOTE: Before working in a new field, you should reset the
system to clear previous field information.
Press UP
ARROW key
Set A
Set B
Press UP
ARROW KEY
Press UP
ARROW key
Figure 24. Parallel swathing with Pass Skips