General Operation

Ag Leader Technology


A + Pattern

Set the angle from true north that you want to swath. As you
begin to make your first pass, press Set A. When you get to the
end of your first pass, turn into your next pass and the lightbar
will guide you on the reverse angle you set.

Pattern: Set to A+ Heading.
Headland pattern: Set to None.
Baseline heading: 315 degrees (Example)

Below is an example of the settings an operator may choose to
establish the desired heading across a field.



Direction of travel
at 315 degrees



























Figure 19. A+ Swath pattern