beautypg.com

Redundant power supply module – HP ProLiant ML350e Gen8 Server User Manual

Page 92

background image

Hardware options installation 92

11.

Install the PCI air baffle into the server ("

Install the PCI air baffle

" on page

29

).

12.

Install the access panel (on page

26

).

13.

Do one of the following:

o

For tower models, return the server to an upright position.

o

For rack models, install the server onto the rails.

14.

Connect each power cord to the server.

15.

Connect each power cord to the power source.

16.

Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.

17.

Do one of the following:

o

For tower models, install the bezel ("

Install the rack bezel

" on page

25

).

o

For rack models, if removed, install the security bezel ("

Security bezel option

" on page

47

).

Redundant power supply module

Power redundancy requires the presence of two power supply modules in the system.

CAUTION:

All power supplies installed in the server must have the same output power capacity.

Verify that all power supplies have the same part number and label color. The system becomes

unstable and may shut down when it detects mismatched power supplies.

Label color

Output

Blue

460 W

Orange

750 W

CAUTION:

To prevent improper cooling and thermal damage, do not operate the server unless

all bays are populated with either a component or a blank.