HP ProLiant ML350e Gen8 Server User Manual
Page 34
Operations 34
CAUTION:
To prevent a server malfunction or damage to the equipment, do not add or remove
the capacitor pack while an array capacity expansion, RAID level migration, or stripe size
migration is in progress.
CAUTION:
After the server is powered down, wait 15 seconds and then check the amber LED
before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do
not remove the cable from the cache module. The cache module is backing up data, and data is
lost if the cable is detached.
To remove the component:
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
" on page
o
For rack models, if installed, remove the security bezel (on page
2.
Power down the server (on page
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.
o
For rack models, extend the server from the rack (on page
5.
Remove the access panel (on page
6.
If installed, remove the PCI air baffle (on page
7.
Remove the system air baffle (on page
8.
If you are removing a capacitor connected to a cache module installed in the system board cache
module connector, first remove any installed PCI cards in slots 3, 4, 5 and 6.
9.
Disconnect the cable from the FBWC module.
10.
Remove the capacitor pack:
o
RPS