HP ProLiant ML350e Gen8 Server User Manual
Page 71
Hardware options installation 71
To install the component:
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
" on page
o
For rack models, if installed, remove the security bezel (on page
2.
Power down the server (on page
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.
o
For rack models, extend the server from the rack (on page
5.
Remove the access panel (on page
6.
If installed, remove PCI air baffle ("
" on page
7.
Remove the system air baffle (on page
8.
Remove any installed full-length PCI cards.
9.
10.
If installed, remove the Mini-SAS cable connected to the system board.
11.
Install the storage controller.
For more information, see the documentation that ships with the option.
12.
Connect the Mini-SAS cable from the drive backplane to the controller card.
For controller-specific instructions, see the controller documentation provided with the storage
controller.
13.
Install the fan cage.
14.
Install the PCI cards that were removed.
15.
Install the system air baffle (on page
16.
Install the PCI air baffle (on page
), if removed.