On a Windows NT 4.0 system running Internet Explorer 6 Service Pack 1, remotely browsing into
a CMS causes a DLL failure after being connected for hours. This issue occurs on a Windows CMS
and on an HP-UX CMS.

Complex systems displaying inconsistency with the number of nPars within
the complex

When viewing the complex through the System Page or Report, the number of nPars represent the
total number of nPars that can potentially be in the complex, regardless of the state of the individual
nPars. Alternatively, when viewing nPars within a complex under a system collection, the number
of nPars associated with a complex is equal to what Systems Insight Manager has determined
through a WBEM provider. Therefore, the number of nPars shown in the system collection might
be less than or equal to the number displayed in the System Page or Report.

Configure or Repair Agents

Configure or Repair Agents tasks that combine Critical, Unknown, and Unmanaged targeted
systems appear to hang at 0% but will eventually complete.

Data collection reports

Data Collection reports might report the network interface for HP-UX systems incorrectly. This is
due to an issue with SNMP agents on HP-UX. In the future, the HP-UX WBEM provider will include
a Link Aggregate Provider to report the network interface on HP-UX systems, and Systems Insight
Manager can then provide the correct data from the WBEM provider.