Operands, Example, Show subcommand – HP XP Array Manager Software User Manual
Page 133: Syntax, Description, 133 description

Operands
Description
Operand
Specifies the user ID for the SVP.
If the user ID includes any non-alphanumeric character, the user ID must be enclosed
by double quotation marks (").
Be sure to specify a user ID that should be used exclusively with the Export Tool. For
detailed information, see “
Requirements for Using the Export Tool
userid
Specifies the password of the user.
If the password includes any non-alphanumeric character, the password ID must be
enclosed by double quotation marks (").
password
Example
This example logs the user expusr into the SVP whose IP address is 158.214.127.170. The password
is pswd.
svpip 158.214.127.170
login expuser pswd
show Subcommand
Syntax
show
Description
The show command outputs the following information to the standard output (for example, to the
command prompt):
•
The period during which monitoring data was collected onto the SVP (storing period)
•
The interval at which the monitoring data was collected (gathering interval).
Performance Monitor collects statistics by the two types of storing periods: in short range and in long
range. In short-range monitoring, the monitoring data between 8 hours and 15 days is stored in the
SVP, and in long-range monitoring, the monitoring data up to three months is stored in the SVP. For
details on the two storing periods, see “
Understanding Statistical Storage Ranges
The show command displays the storing period and the gathering interval for these two types of
monitoring data: in short range and in long range. For example, the show command outputs the
following information:
Short Range
From: 2006/10/01 01:00
-
To: 2006/10/01 15:00
Interval : 1min.
Long Range
From: 2006/09/01 00:00
-
To: 2006/10/01 15:00
Interval : 15min.
Short Range
indicates the storing period and gathering interval of the monitoring data stored in
short range. Long Range indicates those of the monitoring data stored in long range. When you
run the Export Tool, you can export the monitoring data within these periods into files. If you use the
XP24000/XP20000 Performance Monitor User Guide
133