HP StorageWorks XP Remote Web Console Software User Manual
Page 230

Table 51 Troubleshooting Problems with the Status of Logical Paths (continued)
Corrective Action
Description
Path Status
Delete the failed path, and also delete all paths and
remote storage systems not currently in use. The local
The local and remote storage
system rejected the request for
Resource Shortage
(Port)
storage system can be connected to up to 64 remote
creating a logical path
or,
storage systems with up to eight paths to each remote
storage system.
because all resources in the
local and remote storage
Resource Shortage
(Pair-Port)
Make sure all local and remote storage system ports
are properly configured: ordinary target ports or RCU
systems are being used for
other connections.
target ports for hosts, RCU target ports for remote
storage systems, initiator ports for local storage systems.
If necessary, connect to the remote storage system to
delete paths or remote storage systems and reconfigure
the ports, then reconnect to the local storage system.
After that, add the path or the remote storage system
again by using the Add Path window or the Add DKC
window.
Make sure that you entered the correct remote storage
system S/N and path parameters (for example, local
The serial number (S/N) of the
remote storage system does
Serial Number
Mismatch
storage system port, remote storage system port, and
not match the specified serial
number (S/N).
controller ID). After that, delete the failed path. You
may need to change the minimum paths setting or
delete the remote storage system in order to delete the
path. After the deletion finishes, add the path and the
remote storage system again by using the Add Path
window or the Add DKC window.
Make sure that you entered the correct controller ID,
and also make sure that the topology settings of the
local and remote storage system ports are correct.
Make sure that the topology settings of the local and
remote storage system ports are correct.
The specified port is not
configured as an RCP or
Invalid Port
Make sure that you entered the correct remote storage
system S/N and path parameters (for example, local
initiator port, or this path
already exists.
storage system port, remote storage system port, and
controller ID). After that, delete the failed path. You
may need to change the minimum paths setting or
delete the remote storage system in order to delete the
path. After the deletion finishes, add the path and the
remote storage system again by using the Add Path
window and the Add DKC window.
Delete the failed path. You may need to change the
minimum paths setting or delete the remote storage
This path was not established.
system in order to delete the path. After the deletion
finishes, add the path and the remote storage system
again by using the Add Path window and the Add DKC
window.
Make sure that you specified the correct remote storage
system port. Correct the port number if necessary.
The specified port in the
remote storage system is
Pair-Port Number
Mismatch
Make sure that the local storage system port and the
remote storage system port are connected via cables
physically disconnected from
the local storage system.
to each other. If the storage systems are not connected
via cables, connect them via cables and then retry the
operation.
Make sure that the topology settings of ports on the
local and remote storage systems are correct.
Make sure that the specified port in the remote storage
system is configured as an RCU target port. Configure
The specified port in the
remote storage system is not
Pair-Port Type
Mismatch
230 Troubleshooting