HP Insight Management Agents User Manual
Page 36
The following information displays for each controller:
•
Model—Displays the type of controller card.
•
Controller Status—Displays the array controller board status. The following values are valid:
OK—The array controller is operating properly.
◦
◦
General Failure—The array controller has failed.
◦
Cable Problem—The array controller has a cable problem. Check all cables to the
controller.
◦
Powered Off—The array controller does not have power. Replace the controller and
restore power to the controller's slot.
◦
Cache Module Missing—The array controller is operating without a cache module which
is an unsupported configuration. Install a cache module to the controller.
◦
Unknown—Indicates that the Storage Agents are unable to determine the status of the
controller. You may need to upgrade the Storage Agents.
•
Current Role—Displays the array controller's current role for duplexed array controllers. The
following values are valid:
◦
Not Duplexed—This array controller is not duplexed.
◦
Active—This duplexed array controller is the active controller.
◦
Backup—This duplexed array controller is the backup controller.
◦
Unknown—Indicates that the Storage Agents are unable to determine the role of the
controller. You may need to upgrade the Storage Agents.
•
Redundancy Mode—Displays the redundancy type for the controller. The following values are
valid:
◦
Not Redundant—This array controller is not in a redundant configuration.
◦
Driver Duplexing—The array controller is using a controller duplexing algorithm
implemented exclusively in the operating system driver.
◦
Firmware Active/Standby—The array controller is using an active/standby algorithm
implemented in the controller firmware and the operating system driver.
◦
Firmware Primary/Secondary—The array controller is using a primary/secondary
algorithm implemented in the controller firmware and the operating system driver.
◦
Firmware Active/Active—The array controller is using an active/active algorithm
implemented in the controller firmware.
◦
Unknown—Indicates that the Storage Agents cannot determine the redundancy type for
the controller. You may need to upgrade the Storage Agents.
•
Redundancy Error—Displays the redundancy error for the controller. The following values are
valid:
◦
No Failure—No failures have been detected.
◦
No Redundant Controller—No redundant controller is installed.
◦
Different Hardware—The other controller indicates a different hardware model.
◦
No Link—A link to the other controller could not be established.
36
Agent information