Temperature sensors information – HP Insight Management Agents User Manual
Page 116
Temperature Sensors Information
•
Temperature condition—Displays the current temperature condition of the system or client PC.
This value can be:
◦
OK—The temperature is within normal operating range.
◦
Degraded—The temperature is above normal for airflow obstructions. Make sure that the
cover is on.
CAUTION:
Do not operate the system with the cover removed. Proper airflow is possible
only when the cover is in place and properly secured.
◦
Failed—The temperature is outside the normal operating range and could permanently
damage the system. The system automatically shuts down to prevent damage to hardware
or data loss.
NOTE:
A Failed condition does not occur in a client PC since the power supply for the
client is cut off if thermal condition reaches a permanently damaging level.
◦
Unknown— If the Server Agents or the Server Agent cannot determine the status of the
device, you may need to upgrade your driver software. If you are managing a client with
an unknown temperature status, the client may not support thermal detection.
•
Sensor—The number that uniquely specifies the temperature sensor description.
•
Location—This specifies the location of the temperature sensor present in the system.
•
Temperature—This is the current temperature sensor reading in degrees Celsius.
•
Threshold—This is the shutdown threshold temperature sensor setting in degrees Celsius. This
is the temperature at which the sensor is considered to be in a failed state causes the system
to be shutdown.
NOTE:
Only the Ambient zone type allows setting of the threshold temperature. Not all
(maybe one or none) sensors can set this value.
•
Type—This specifies the type of this instance of temperature sensor. This value can be:
Blowout—If a blowout temperature sensor reaches its threshold, the fan or fans in the
area of the temperature sensor increases in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.
◦
◦
Caution—If a caution temperature sensor reaches its threshold, the temperature condition
is set to degraded and the system either continues or shuts down depending on the setting
of the Thermal Degraded Action.
◦
Critical—If a critical temperature sensor reaches its threshold, the Temperature Condition
is set to failed and the system shuts down.
◦
Unknown—The Temperature threshold type could not be determined.
116
Agent information