beautypg.com

Raid 0+1 – HP StorageWorks 3000 RAID Array User Manual

Page 54

background image

2-12 RAID Array 3000 Controller Shelf Hardware User’s Guide

Compaq Confidential – Need to Know Required

Writer: Bob Young Project: RAID Array 3000 Controller Shelf Hardware User’s Guide Comments:

Part Number: EK-SMCPQ-UG. D01 File Name: c-ch2 RAID Array 3000 Controller.doc Last Saved On: 12/4/00 1:08 PM

RAID 0+1

RAID 0+1 (see Figure 2– 7) combines RAID 0 (striping) with RAID 1
(mirroring). In RAID 0+1 write, the controller breaks up the data block from
the host into smaller chunks, then writes the chunks to half the drives in the
array, while writing duplicate chunks to the remaining drives.

1110

1101
1011

Host Data

Controller divides

the data into

chunksized units

1110
1101
1011

Striped data written
to half the drives

Striped data mirrored
to the remaining drives

SHR-1056

Figure 2-7. Diagram of RAID 0+1 write

In the event of a drive failure, a RAID 0+1 array will enter degraded mode and
continue to operate by substituting the failed drive with its mirror.