beautypg.com

HP Storage Mirroring V5 Software User Manual

Page 57

background image

7

-

3

4.

You must validate that your target is compatible with your source and can stand-in if the source fails. Click

Validate

configuration

. You can also select

Actions

,

Validate

. The

Validation

tab at the bottom of Full-Server Failover Manager

updates to display the validation check. Errors are designated by a white X inside a red circle. Warnings are designated
by a black exclamation point (!) inside a yellow triangle. A successful validation is designated by a white checkmark inside
a green circle.

Double-click on any of the validation items to see details. You must correct any errors before you can enable protection.
Depending on the error, you may be able to click

Fix

or

Fix All

and let Full-Server Failover correct the problem for you.

You can also select

Actions

,

Fix Validation Issues

or

Actions

,

Fix All Validation Issues

. For those errors that

Full-Server Failover cannot correct automatically, you will need to modify the target to correct the error, or you can
select a different target. You must revalidate the selected servers until the validation check passes without errors.

5.

Once the validation check passes without errors, click

Enable Protection

to begin monitoring. You can also select

Actions

,

Enable Protection

.

NOTE:

If you have a Full-Server Failover connection established, do not create any Storage Mirroring connections from
the Full-Server Failover source or target.