3.

Do not modify the SNMP configuration for VC Domain level. The default SNMP
configuration for VC Domain level is Enabled with the Community String equaling Public.
This is only available through the Virtual Connect Manager Command line interface.

Fibre Channel Port Speed cannot be set to 8Gb for a HP Virtual Connect 8-Gb 20-Port Fibre
Channel Module.

Select any value other than 8Gb as the uplink configuration speed when defining a SAN
Fabric for a HP Virtual Connect 8 Gb 20 Port Fibre Channel Module.

Figure 3-10 Select any value other than 8Gb as uplink and downlink configuration speeds

Select any value other than 8 Gb as the downlink configuration speed when assigning a SAN
Fabric for a HP Virtual Connect 8 Gb 20-Port Fibre Channel Module.

VC Domain tasks

From the VC Domains page, you can perform the following tasks:

License an enclosure for VCEM

Create a VC Domain Group

Add a VC Domain to a VC Domain Group

Remove a VC Domain from a VC Domain Group

VC Domain Maintenance

Cancel VC Domain Maintenance

Resynchronize a VC Domain with Configuration Mismatch Status

VCEM cabinet licensing

You must purchase a license for each enclosure to be managed. For licensing information, see the
VCEM QuickSpecs at

http://www.hp.com/go/vcem

To enable a VC Domain license, select from one of the following options:

For new VC Domain Groups:
1.

Click New VC Domain Group from the VC Domain page. An area showing both licensed
and unlicensed VC domains is displayed.

2.

Click Add Key and enter the key string.