Server profiles are not displaying physical port mapping and allocated
bandwidth information

VCEM does not display physical port mapping and allocated bandwidth information for the Ethernet
network connection in a server profile.

To correct this information, perform the following:

1.

Go to Virtual Connect Manager user interface.

2.

Expand the Server Profiles Assigned Server Profiles left navigation panel and click the
desired server profile.

3.

The Physical Port Mapping and Allocated Bandwidth information is presented inside the
Ethernet Network Connection table.

VCEM page displays "Communication with the Systems Insight Manager
server has been lost"

When VCEM performs a task that requires some time to be completed, Systems Insight Manager
server might detect that the task is taking too long and the Communication with the Systems
Insight Manager server has been lost

message appears.

This behavior is intermittent, but can occur in the following situations:

When navigating through VCEM pages and requesting multiple operations at the same time

When VC Domains that are being managed by VCEM are having a communication outage

To solve this issue, press Refresh to reload the VCEM page, and then perform the desired operation
again.

To prevent the issue from happening again, perform either of the following:

Verify that the Central Management Server has the minimum hardware requirements to run
VCEM.

Verify that all VC Domains are correctly communicating with the Central Management Server.

VC Domain not discovered by Systems Insight Manager

If SNMP protocol is not correctly configured, then Systems Insight Manager cannot correctly discover
the unconfigured VC Domains, and then you might not be able to see such VC Domains or the VC
Domains list.

To correct this issue, perform one of the following:

Access the Systems Insight Manager menu, select Options

DiscoveryConfigure Global

Credentials

, and verify the first SNMP read community string is public.

Access the Systems Insight Manager menu, Select Options

DiscoveryConfigure Global

Protocol Settings

, and verify that the Enable SNMP option is selected.

Run Systems Insight Manager discovery on the Onboard Administrator IP address related to
the VC Domain by accessing the Systems Insight Manager menu and selecting
Options

Identify System or OptionsDiscovery.

Create VC Domain Group or Add VC Domain to VC Domain Group
operations fail and the message "An invalid boot LUN was entered. Check
the storage arrays for the proper LUN number" appears

VCEM requires the boot target LUN configuration and server profiles to be either a three-digit
decimal between 0–255, or a 16-digit hexadecimal value between 0 and FFFFFFFFFFFFFFFF.

This message appears whenever a Create VC Domain Group or an Add VC Domain to VC Domain
Group operation is performed and there is one or more server profiles inside the VC Domains that
have a boot LUN that does not comply with the required conditions.