beautypg.com

Removing flex-10 iscsi connections – HP Insight Management-Software User Manual

Page 31

background image

Virtual Connect 3.10 features that must be disabled in a VC Domain to be part of
the VC Domain Group with Virtual Connect firmware 3.0x, 2.3x and 2.1x

NOTE:

To disable any of the FC SAN or Flex-10 iSCSI features, the last connection in the feature

table must be deleted first.

Flex-10 iSCSI Connections are not supported.

To disable this feature:

1.

Log on to HP Virtual Connect Manager.

2.

Expand Server Profiles in the navigation pane and select the server profile with Flex-10
iSCSI connections.

3.

Right-click on the last Flex-10 iSCSI connection and select Delete Connection as displayed
in the following figure:

Figure 3-2 Removing Flex-10 iSCSI Connections

4.

Continue selecting the last Flex-10 iSCSI connection until all connections are removed.

Virtual Connect 3.0x features that must be disabled in a VC Domain to be part of
the VC Domain Group with Virtual Connect firmware 2.1x and 2.3x

NOTE:
Keep the following in mind:

VC 3.0x features must be disabled in order for the firmware to reside in the same groups as
VC 2.3x or 2.1x firmware versions.

All Virtual Connect 2.3x features not supported by VC firmware 2.1x must be disabled.

Multi-blade FC servers are not supported.

Do not configure server profiles assigned to multi-blade servers with more FC SAN connections
than the number of Virtual Connect Fibre Channel modules available in the VC Domain. The

Requirements for adding a VC Domain to a VC Domain Group

31

This manual is related to the following products: