Virtual Connect 3.10 features that must be disabled in a VC Domain to be part of
the VC Domain Group with Virtual Connect firmware 3.0x, 2.3x and 2.1x
NOTE:
To disable any of the FC SAN or Flex-10 iSCSI features, the last connection in the feature
table must be deleted first.
•
Flex-10 iSCSI Connections are not supported.
To disable this feature:
1.
Log on to HP Virtual Connect Manager.
2.
Expand Server Profiles in the navigation pane and select the server profile with Flex-10
iSCSI connections.
3.
Right-click on the last Flex-10 iSCSI connection and select Delete Connection as displayed
in the following figure:
Figure 3-2 Removing Flex-10 iSCSI Connections
4.
Continue selecting the last Flex-10 iSCSI connection until all connections are removed.
Virtual Connect 3.0x features that must be disabled in a VC Domain to be part of
the VC Domain Group with Virtual Connect firmware 2.1x and 2.3x
NOTE:
Keep the following in mind:
•
VC 3.0x features must be disabled in order for the firmware to reside in the same groups as
VC 2.3x or 2.1x firmware versions.
•
All Virtual Connect 2.3x features not supported by VC firmware 2.1x must be disabled.
•
Multi-blade FC servers are not supported.
Do not configure server profiles assigned to multi-blade servers with more FC SAN connections
than the number of Virtual Connect Fibre Channel modules available in the VC Domain. The
Requirements for adding a VC Domain to a VC Domain Group