6.

Access the Onboard Administrator web interface for the enclosure to verify that the VC Domain
link in the bottom left portion of the screen correctly points to the VC Domain Manager IP
address.

7.

Perform an Systems Insight Manager discovery against the Onboard Administrator IP address.

8.

From the VCEM home page, click the VC Domains tab.

9.

Select the same VC Domain, and then click Add to VC Domain Group. Wait for the job to
complete successfully.

Verify that the VC Domain meets the requirements for adding a VC Domain to a VC Domain
Group.

For more information, see

“Requirements for adding a VC Domain to a VC Domain Group”

(page 27)

.

Failover fails to initiate with an ERROR (30) - Could not initiate failover;
nested exception is: java.net.SocketTimeoutException: Read timed out

This error can occur when the CLI cannot communicate to the VCEM SOAP interface. This
communication issue can occur when an IP address or hostname lookup takes more than a few
minutes to return or when there is a networking issue on the VCEM server. To resolve this issue,
verify that the Systems Insight Manager system is running properly by logging in and that the IP
address or hostname for the source system exists. If the IP address or hostname does not exist,
perform an Systems Insight Manager discovery.

VC Profile Failover fails during Onboard Administrator replacement

If an enclosure has two Onboard Administrators with redundancy and one fails, then the redundant
Onboard Administrator might take several minutes to take over. The VC Profile Failover operation
fails when source or spare bays are associated to an enclosure while the redundant Onboard
Administrator is still in the process of taking over.

To resolve this issue:

1.

Wait until Onboard Administrator has failed over. Perform an Systems Insight Manager
discovery to rediscover the new Onboard Administrator IP address. If the address is not
rediscovered, see the HP BladeSystem c-Class Onboard Administrator User Guide.

2.

If you initiated VC Profile Failover through the VCEM GUI:
a.

From the VCEM home page, click the Profiles tab.

b.

Select the server profile to failover and click Failover. The Virtual Connect
Enterprise Manager is executing the request

message appears.

c.

Click OK to go to the Jobs page and monitor job progress.

VCEM cannot power down ProLiant server model BL465 G1

All VCEM operations that explicitly power down the server (such as VC Profile Failover, Momentary
Press or Press and Hold) might not work well for ProLiant server model BL465c G1 unless the
Onboard Administrator firmware version is 2.25. If you are managing enclosures that contain
ProLiant server model BL465c G1, verify that you use Onboard Administrator firmware version
2.25.

After a VC Domain is removed from a VC Domain Group in VCEM, a
profile with external-managed status cannot be edited through Virtual
Connect Manager

This situation occurs when the profile address is not in the released range selected during the
remove VC Domain from VC Domain Group or delete entire VC Domain Group operations. To

Failover fails to initiate with an ERROR (30) - Could not initiate failover; nested exception is: java.net.SocketTimeoutException:

Read timed out

113