Reboot Required :Yes
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
NIC HP Embedded Network Adapter Yes Success (Reboot Pending)
--------------------------------------------------------------------------------

Power management controller

Example 35 Firmware update of the power management controller on 9730 and X9720 platforms

# hpsp_fmt –f –c Power_Mgmt_Ctlr
Flashing Power_Mgmt_Ctlr: Based on the configuration, it may take 5 minutes.
<<< Succeeded >>>
--------------------------------------------------------------------------------
Device :Power_Mgmt_Ctlr
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for Power Management Controller
using CP013163.scexe. The system must be
restarted to complete the operation.
Reboot Required :Yes
Coordinated Reboot Required :No
--------------------------------------------------------------------------------

SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
Power_Mgmt_Ctlr Power Management Controller Yes Success (Reboot Pending)
--------------------------------------------------------------------------------

Embedded smart array controller (P410i)

Example 36 Firmware update of the embedded smart array controller (P410i) on 9730 and X9720
platforms

# hpsp_fmt -f -c smart_array_ctlr
Flashing Smart_Array_Ctlr: Based on the configuration, it may take 10 minutes.
<<< Succeeded >>>

--------------------------------------------------------------------------------
Device :Smart_Array_Ctlr
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for HP Embedded Smart Array
Controller using CP017183.scexe. The system must
be restarted to complete the operation.
Reboot Required :Yes
Coordinated Reboot Required :No
--------------------------------------------------------------------------------

SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
Smart_Array_Ctlr HP Embedded Smart Array Yes Success (Reboot Pending)
Controller
--------------------------------------------------------------------------------

46