By category (server/storage), Single component, By category (server/storage) single component – HP StoreAll Storage User Manual
Page 25: By category (server/storage)

Example 9 Get the firmware update recommendation on all components
# hpsp_fmt -fr all
Based on the configuration, Flash recommendation may take 20 minutes.
<<< Completed >>>
By category (server/storage)
Use the component category with the get firmware recommendation command as follows:
•
To get the firmware recommendation for all server components:
# hpsp_fmt –fr server
•
To get the firmware recommendation for all storage components:
# hpsp_fmt –fr storage
Example 10 Get firmware recommendations for 8200 server components
# hpsp_fmt –fr server
Based on the configuration, Flash recommendation may take 5 minutes.
<<< Completed >>>
Single component
To get the firmware update recommendation for a single component, use the –c
option along with the –fr option as follows:
# hpsp_fmt –fr –c
The possible component name can be the short form of components shown in the -lc command
output. See the section
“Listing supported components” (page 20)
. The example output shows the
short form on the left-hand side and its description on the right-hand side.
NOTE:
The same short form is used for the device field/column of all operations.
Obtaining the update (flash) recommendation
25