Obtaining the update (flash) recommendation, All components, Syntax – HP StoreAll Storage User Manual
Page 24: Description
Example 8 Discover the active firmware version of a set of components for the 8800 platform
# hpsp_fmt -d -c iLO4, Enclosure_IO_Mod, PCIeNIC, SERVER_HDD
Based on the configuration, FW discovery may take 15 minutes.
<<< Completed >>>
Obtaining the update (flash) recommendation
Syntax
--flashrec
-fr
Description
The output of the --flashrec command includes the recommended action and the severity of
the recommended action. The update recommendation action can be one of the following:
•
UPGRADE: The active firmware version of the component is lower than the qualified version
and should be upgraded.
•
DOWNGRADE: The active firmware version of the component is higher than the qualified
version and should be downgraded.
•
NONE: The active firmware version of the component is equal to the qualified version. No
action is needed unless you want to force a rewrite of the firmware in the case of the current
firmware being corrupt.
The severity of the recommended action can be one of the following:
•
MANDATORY: It is critical to update the firmware for optimal performance and system stability.
•
RECOMMENDED: It is optional to update the firmware from a functionality standpoint. However,
it is highly recommended to update the firmware for system stability.
The output also contains information about the reboot requirement of a component for a successful
firmware update, where necessary.
A verbose report includes additional information such as approximate flash duration, dependent
components, and so on.
All components
To get the flash firmware recommendation for all components, run the following command:
# hpsp_fmt -fr all
24
StoreAll 8800 and 8200 FMT command reference and examples