All server components – HP StoreAll Storage User Manual

Page 31

background image

2.

On node 2, run hpsp_fmt –f –c Storage_Ctlr.

3.

Reboot node 1 and node 2 together and wait for them to completely power up.

All server components

When upgrading the storage controllers in the 8800 couplet using the command to upgrade all
server components, complete the upgrade as follows:
1.

Fail over to node 2. See “Failing a server over manually” in the Administrator Guide for your
platform.

2.

On node 1, run the -f server command as shown in the following example:

Example 19 Firmware update of all server components on 8800 platforms

# hpsp_fmt -f server
INFORMATION: While flashing 331FLR NIC card, you may experience temporary
network disruption if you are connected through its interfaces.
Please read through the following WARNING messages before continuing with the updates:
***WARNING***
- While flashing SERVER_HDD, the smart-component might also flash some of the Enclosure_HDD drive models
if supported by the same smart-component.
- And also, while flashing Enclosure_HDD, the smart-component might also flash some of the SERVER_HDD
drive models
if supported by the same smart-component.

Please confirm you have read all the above warning messages and taken necessary actions (Y/N)?y

Do you want to proceed (Y/N)?y
Flashing ILO4: Based on the configuration, it may take 10 minutes.
<<< Not attempted >>>
Flashing BIOS: Based on the configuration, it may take 5 minutes.
<<< Succeeded >>>
Flashing Power_Mgmt_Ctlr: Based on the configuration, it may take 5 minutes.
<<< Not attempted >>>
Flashing Smart_Array_Ctlr: Based on the configuration, it may take 10 minutes.
<<< Not attempted >>>
Flashing NIC: Based on the configuration, it may take 10 minutes.
<<< Not attempted >>>
Flashing PCIeNIC: Based on the configuration, it may take 10 minutes.
<<< Not attempted >>>
Flashing Storage_Ctlr: Based on the configuration, it may take 10 minutes.
<<< Not attempted >>>
Flashing SERVER_HDD: Based on the configuration, it may take 5 minutes.
<<< Not attempted >>>

----------------------------------------------------------------------------------------------------
Device :ILO4
Status :Flash Not Attempted
Code :0x1028
INFORMATION :Flash not attempted for Integrated Lights-Out (iLO) 4 using
iLO4_FW_LNXSC_130-CP018365.scexe: the firmware version (1.30) is
already up to date for device. However, you may still force the
install of the firmware by specifying the option '--force'.
Reboot Required :No
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------
Device :BIOS
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for BIOS using CP021628.scexe. The system must be
restarted to complete the operation.
Reboot Required :Yes
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------
Device :Power_Mgmt_Ctlr
Status :Flash Not Attempted
Code :0x1028
INFORMATION :Flash not attempted for Power Management Controller using
CP021105.scexe: the firmware version (3.2) is already up to date for
device. However, you may still force the install of the firmware by
specifying the option '--force'.
Reboot Required :No
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------
Device :Smart_Array_Ctlr
Status :Flash Not Attempted
Code :0x1028
INFORMATION :Flash not attempted for HP Embedded Smart Array Controller using
CP021158.scexe: the firmware version (4.68) is already up to date for
device. However, you may still force the install of the firmware by
specifying the option '--force'.
Reboot Required :No
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------

Updating firmware