Bios, Integrated lights-out (ilo), Embedded network adapter – HP StoreAll Storage User Manual

Page 28

background image

“Storage controller” (page 30)

“All server components” (page 31)

BIOS

Example 13 Firmware update of the BIOS on 8800/8200 platforms

# hpsp_fmt -f -c BIOS
Flashing BIOS: Based on the configuration, it may take 5 minutes.
<<< Succeeded >>>

----------------------------------------------------------------------------------------------------
Device :BIOS
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for BIOS using CP021628.scexe. The system must be
restarted to complete the operation.
Reboot Required :Yes
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------

SUMMARY:
----------------------------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
----------------------------------------------------------------------------------------------------
BIOS BIOS Yes Success (Reboot Pending)

----------------------------------------------------------------------------------------------------

At this stage, you can optionally reboot the server to activate the updated firmware or wait for
other firmware updates, if any, and perform one reboot for them all.

Integrated Lights-Out (iLO)

Example 14 Firmware update of the iLO on 8800/8200 platforms

# hpsp_fmt -f -c ILO4
Flashing ILO4: Based on the configuration, it may take 10 minutes.
<<< Succeeded >>>

----------------------------------------------------------------------------------------------------
Device :ILO4
Status :Success
Code :0x1000
SUCCESS :Flash succeeded for Integrated Lights-Out (iLO) 4 using
iLO4_FW_LNXSC_130-CP018365.scexe
Reboot Required :No
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------

SUMMARY:
----------------------------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
----------------------------------------------------------------------------------------------------
ILO4 Integrated Lights-Out (iLO) 4 No Success

----------------------------------------------------------------------------------------------------

Embedded network adapter

NOTE:

If you are flashing a 331FLR NIC, you may experience temporary network disruption if

you are connected through its network interface.

28

StoreAll 8800 and 8200 FMT command reference and examples