Returning the failed component, Replacing the disk enclosure power supply/blower, Checking model number and firmware version – HP 3000 Enterprise Virtual Array User Manual
Page 95: Figure 40, Adding the disk to a disk group
Click Disk Storage Systems under Storage, and then select the appropriate product under
EVA Disk Arrays.
If the disk is running an unsupported version of firmware, download the correct firmware from
the following website and install it using the instructions included with the firmware file. Do not
add the disk to a disk group if it is running an unsupported firmware version.
NOTE:
When downloading the firmware, use the disk model number to locate the correct firmware
file. If you have difficulty locating the correct firmware, contact your HP-authorized service
representative for assistance.
If you are running XCS 6.000, verify that leveling is not in progress before upgrading the disk drive
firmware. In HP Command View EVA, go to the General tab of the Disk Group Properties window
and verify that the Leveling field displays Inactive. If it displays Active, wait for leveling to complete
before performing the upgrade. This does not apply if you are running XCS 6.100 or later.
Figure 40 Checking model number and firmware version
Adding the disk to a disk group
After replacing the disk, add it to a disk group. The disk is typically added back into its original disk
group.
1.
In the Navigation pane, select Storage system > Hardware > Rack > Disk enclosure > Bay.
2.
In the Content pane, select the Disk Drive tab.
3.
Click Group to initiate the process for adding the disk to a disk group.
Operation Successful
is displayed indicating the disk is now grouped and leveling has
been initiated. The storage system begins immediately using the disk.
NOTE:
If the Device Addition Policy is set to automatic, the disk is automatically added to a disk group. In
this case the Group option will not be available.
Returning the failed component
Follow the return instructions provided with the new component.
Replacing the disk enclosure power supply/blower
This section describes the procedure for replacing the power supply/blower assembly.
HP StorageWorks 3000/5000 Enterprise Virtual Array user guide (VCS 4.xxx)
95