F.en.04 critical condition—transceiver removed, Voltage sensor and current sensor conditions, Voltage and current sensor locations – HP 3000 Enterprise Virtual Array User Manual
Page 133
0.F.en.03 CRITICAL condition—Transceiver fibre channel drive enclosure bus fault
The system has detected a Fibre Channel drive enclosure bus fault involving a transceiver. This error
prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Check all the transceivers and cables to ensure they are properly connected.
3.
Check all the transceivers on the loop to ensure they are compatible with the I/O module.
4.
If the problem persists, contact your HP authorized service representative.
0.F.en.04 CRITICAL condition—Transceiver removed
The EMU detects that a transceiver has been removed. This error remains active until the problem is fixed.
The error can be cleared by doing one of the following:
1.
Install a new transceiver,
or
Reconfigure the system by switching from a loop topology to one with Vixel switches, then the
transceiver is not necessary.
2.
Clear the error by resetting the EMU or by removing and then re-installing the I/O module.
0.F.en.05 CRITICAL condition—Invalid fibre channel character
This symptom can occur under the following conditions:
•
The incoming data stream is corrupted.
•
A cable is not completely connected.
•
The signal is degraded.
This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop
capability. This error remains active until the problem is fixed.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
Voltage sensor and current sensor conditions
The format of these sensor condition reports is 1.2.en.ec for a voltage sensor, and 1.3.en.ec for a
current sensor, where:
•
1.2. is the voltage sensor element type
•
1.3. is the current sensor element type number
•
en. is the sensor element number
•
ec is the error code
lists the location of the power supply voltage and current sensors.
Table 51 Voltage and current sensor locations
Sensor
Sensor Element Location
01.
Power Supply 1 +5 VDC
02.
Power Supply 1 +12 VDC
03.
Power Supply 2 +5 VDC
04.
Power Supply 2 +12 VDC
HP StorageWorks 3000/5000 Enterprise Virtual Array user guide (VCS 4.xxx)