03 unrecoverable condition—power supply shutdown, 04 information condition—emu internal data, 05 unrecoverable condition—backplane nvram – HP 3000 Enterprise Virtual Array User Manual

Page 129: 10 noncritical condition—nvram invalid read data, 11 noncritical condition—emu nvram write failure

background image

4.

If resetting the EMU did not correct the problem, replace the EMU.

5.

If unable to correct the problem, contact your HP authorized service representative.

0.7.01.03 UNRECOVERABLE Condition—Power supply shutdown

This message only appears in HP Command View EVA to report a power supply has already shut

down. This message can be the result of the controller shutdown command or an EMU or power supply

initiated power shutdown.
This message cannot be displayed until after restoration of power. Therefore, there is no corrective

action required.

0.7.01.04 INFORMATION condition—EMU internal data

The EMU is unable to collect data for the SCSI-3 Engineering Services (SES) page. This condition report

remains active for 15 seconds. The condition report affects only internal EMU operations. There is no

degradation of enclosure operations.
The EMU initiates automatic recovery procedures.
If the problem is not automatically corrected after one minute, contact your HP authorized service

representative.

0.7.01.05 UNRECOVERABLE condition—Backplane NVRAM

NOTE:

IMPORTANT

Backplane

NVRAM errors usually occur during manufacture. At this time they are identified and

corrected. They rarely occur during normal operation.

When a

backplane

NVRAM is not programmed or cannot be read by the EMU, there is no

communication with the disk drives. This condition report remains active until the problem is corrected.
Complete the following procedure to correct this problem.

1.

Record all six characters of the condition report.

2.

Reset the EMU.

3.

Observe the EMU to ensure the error is corrected.

4.

If resetting the EMU did not correct the problem, contact your HP authorized service representative.

0.7.01.10 NONCRITICAL condition—NVRAM invalid read data

The data read from the EMU NVRAM is invalid. This error initiates an automatic recovery process. This

condition report remains active until the problem is corrected.
If the automatic recovery process does not correct the problem, complete the following procedure.

1.

Record all six characters of the condition report.

2.

Reset the EMU.

3.

Observe the EMU to ensure the error is corrected.

4.

If resetting the enclosure did not correct the problem, contact your HP authorized service

representative.

0.7.01.11 NONCRITICAL condition—EMU NVRAM write failure

The EMU cannot write data to the NVRAM. This condition report remains active until the problem is

corrected.

HP StorageWorks 3000/5000 Enterprise Virtual Array user guide (VCS 4.xxx)

129