Emu indicator displays, Using the alphanumeric display, Emu status indications – HP 3000 Enterprise Virtual Array User Manual

Page 56: Emu led displays

background image

EMU indicator displays

The EMU status indicators are located above the alphanumeric display. See

Figure 17

. These indicators

present the same information as those on the front, lower right corner of the enclosure.
You can determine the EMU and enclosure status using the information in

EMU LED displays table

.

Table 15 EMU status indications

EMU indicator

(green)

Power indicator

(green)

Fault indicator

(amber)

Status and recommended actions

Flashing

Flashing

Flashing

The EMU Locate function is active. This

display has precedence over all others.

Fault conditions cannot be displayed when

the Locate function is active.

Flashing

On

Off

The EMU is operational. The enclosure

power (both +5 VDC and +12 VDC) is

present and correct. There are no enclosure

faults.

Flashing

On

On

The EMU is operational. There is an

enclosure fault. Check the alphanumeric

display error code for information about

the problem.

Flashing

Off

Off

The EMU is operational. This display may

be present when power is initially applied

to the enclosure. Note: When the +5 VDC

is incorrect, all the indicators are off.

On

On

Off

There is an EMU fault. There is no enclosure

fault.

Off

On

Off

There is an EMU fault. There is no enclosure

fault.

Off

Off

Off

There is an enclosure fault. Either +5 VDC

is incorrect, or both +5 VDC and +12 VDC

are incorrect. Other error conditions may

exist.

Using the alphanumeric display

The two-character alphanumeric display is located at the top of the EMU (see

Figure 17

). This

seven-segment display provides information about multiple enclosure functions. The push buttons control

the data displayed or entered.

Alphanumeric display description

The top-level, two-character alphanumeric display (En, Li, rG, Au, and Er), is the display group. The

function of the other displays is display-group dependent. The default display is the enclosure number, a

decimal number in the range 00 through 14. The push buttons allow you to select the alphanumeric

display or to enter data.

The bottom push button sequentially moves between groups and selects a display group .

See

EMU display groups

for a description of these display groups.

The top push button moves between the levels within a display group (see 2,

Figure 17

).

Display groups

When you press and release the bottom push button, the alphanumeric display selects a different display

group.

EMU display groups

describes the display groups.