Changing the Device Addition Policy

To prevent the storage system from automatically grouping a new disk drive that may have the incorrect

firmware on it, the Device Addition Policy must be checked and set to manual if necessary:

1.

Open Command View VA and in the Navigation pane select the storage system.

The Initialized Storage System Properties window opens.

2.

Click System Options.

3.

Select Set system operational policies.

4.

If the Device Addition Policy is set to Automatic, change it to Manual.

5.

Click Save changes.

NOTE:

If you want to return the Device Addition Policy to automatic, use the above procedure to do so after

verifying the disk drive has the correct firmware version.

Installing the disk drive

1.

Push in the ejector button on the disk drive and pull the release lever down to the full open position.

2.

Insert the drive into the enclosure as far as it will go (1,

Figure 8

).

3.

Close the release lever until it engages the ejector button, and the disk drive seats in the backplane

(2,

Figure 8

).

4.

Press in firmly on the disk drive to ensure it is seated properly.

1

1

2

0116a

Figure 8 Installing the disk drive

Checking status indicators

After replacing the disk drive, check the following to verify that the disk drive is operating normally:

NOTE:

It may take up to 10 minutes for the component to display good status.

Check the disk drive status indicators. See

Figure 9

.

• Activity indicator (1) should be on or flashing
• Online indicator (2) should be on or flashing
• Fault indicator (3) should be off

Check the following using HP Command View EVA.

42

Enterprise Virtual Array operation