HP XP P9500 Storage User Manual
Page 97
![background image](/manuals/396883/97/background.png)
Table 39 P9500 response characteristics to failure conditions (continued)
FREEZE function
Expected messages
Continuous
Access
Synchronous Z
pairs
suspended?
Failure condition
(2) One (or more) IEA494 messages showing
EXTENDED LONG BUSY are displayed.
affected LCU
pairs.
(3) One (or more) IEA491 and IEA494 messages
showing PAIR SUSPENDED are displayed.
* When one side of the MCU cache is blocked, duplex Continuous Access Synchronous Z pairs are not affected, but
pending duplex Continuous Access Synchronous Z pairs are suspended. Suspending Continuous Access Synchronous
Z pairs with pending duplex status provides additional protection in the unlikely event of a cache failure.
GDPS Continuous Access Synchronous Z Compatible XRC matrix
shows the functional comparison between IBM 3990 6E, P9500,
XP24000/XP20000 Disk Array, and XP12000 Disk Array/XP10000 Disk Array about the function
of GDPS support, PPRC and XRC.
NOTE:
The information shown in
may not be current. Please contact your
HP account team for the latest GDPS Continuous Access Synchronous Z Compatible XRC matrix
information.
Table 40 GDPS Continuous Access Synchronous Z Compatible XRC matrix
XP24000/XP20000 Disk
Array,
P9500
IBM 3990 6E
Feature
XP12000 Disk
Array/XP10000 Disk Array
GDPS
Supported
Supported
Supported
Planned outage
Supported
Supported
Supported
Unplanned outage using
IEA494I
Default time for FREEZE is
120 sec, optional user
Default time for FREEZE is
120 sec, optional user
Default time of 120 sec for
FREEZE after IEA494I
message is issued.
IEA494I Long Busy message
defined from 0 to 600 sec
defined from 0 to 600 sec
after IEA494I message is
issued.
after IEA494I message is
issued.
Table 41 GDPS Continuous Access Synchronous Z Compatible XRC matrix
XP24000/XP20000 Disk
Array,
P9500
IBM 3990 6E
Feature
XP12000 Disk
Array/XP10000 Disk Array
Cnt Ac-S Z
Continuous Access
Synchronous Z
PPRC
Peer-to-Peer Remote Copy
XP24000/XP20000 Disk
Array and XP12000 Disk
P9500, XP24000/XP20000
Disk Array, and XP12000
3990-6 to 3990-6
Hardware based
Array/XP10000 Disk Array
Disk Array/XP10000 Disk
to XP24000/XP20000 Disk
Array to P9500,
Array and XP12000 Disk
Array/XP10000 Disk Array.
XP24000/XP20000 Disk
Array and XP12000 Disk
Array/XP10000 Disk Array.
P9500 response characteristics to failure conditions
97