HP XP P9500 Storage User Manual
Page 109
•
Time-Saving Mode flag: “Yes” = The Use Time-Saving Mode option is enabled; “No” = The
Use Time-Saving Mode option is disabled; default = “Yes”. This parameter is a non-list type
and only one value can be specified.
•
Differential management measurement flag list (string): The differential between the volumes
is managed in cylinder (“Cylinder” or “C”) or in track (“Track” or “T”). When “Auto” or “A”
is specified, the storage system selects the differential management measurement (cylinder or
track) automatically. The default is Auto.
•
Time stamp transfer list (string): “Enable” = The host I/O timestamp is transferred from M-VOL
to R-VOL; “Disable” = The host I/O timestamp is not transferred from M-VOL to R-VOL; default
= “Disable”. For the async pairs you must omit this parameter.
The CreateHrcPair Command example that follows
provides an
example of the pair macro commands needed to create the specified pairs with the parameters
listed in the table.
CAUTION:
When using the CreateHrcPair command to create more than one pair, make
sure to keep each line within the maximum line length (320 bytes).
Table 53 CreateHrcPair parameters
Value
Parameter
_ilDevA
M-VOL
_slWorkA
Serial number (RCU)
11
SSID (RCU)
_ilDevB
R-VOL
_slWorkB
Initial copy pace
E
Initial copy mode
S0, S0, S0
Sync level
_ilWorkA
Priority
Never
Fence level
0
CFW flag
1
DFW flag
[omit – default]
Time-Saving Mode
Enable
Time stamp transfer
The full example of the pair macro commands needed to create the specified pairs with the
parameters listed in
is shown in two parts in the following two examples.
Operation macro commands 109