HP XP P9500 Storage User Manual
Page 48
![background image](/manuals/396883/48/background.png)
6.
In the RCU S/N box, enter the remote CU’s 5-digit serial number.
7.
In the Controller ID box, select the remote system’s controller ID.
8.
In the Logical Adr. (RCU CU) box, enter the CU number of the RCU being added. The CU
number differs by the specified controller ID, as follows:
•
When the specified controller ID is 6 (P9500) or 5 (XP24000/XP20000 Disk Array), you
can select a CU number from 00 to FE.
•
When the specified controller ID is 4 (XP12000 Disk Array/XP10000 Disk Array), you
can select a CU number from 00 to 3F.
9.
In the SSID boxes, enter the SSID(s) of the RCU being added. The P9500 uses one SSID for
each set of 256 volumes and one SSID for each set of 64 volumes or four SSIDs per CU. SSID
is 4-FFFF (hexadecimal).
10. In the M-R Path box, define the logical path between local and remote systems. You can define
a maximum or eight logical paths to an RCU.
1.
In the Port column, select a local system initiator port, which you previously set up.
2.
In the Pair-Port column, select the remote system RCU target port, also previously set up.
This establishes a logical path between the ports.
You can abbreviate the number to two characters. For example, “1A” can be entered instead
of “CL1-A”. Letters can be uppercase or lowercase.
11. Click Option. The RCU Option dialog box displays.
48
Configuration operations