beautypg.com

Cache failure, Unregistered error code for tpc-r, Cache failure unregistered error code for tpc-r – HP XP P9500 Storage User Manual

Page 24

background image

The Basic HyperSwap function performed from TPC-R may fail, when the FREEZE command process
does not complete within 20 seconds. We recommend the following conditions to complete the
FREEZE command process within 20 seconds.

(Number of Host paths) x (Number of LPARs) x (Number of CGROUPs (Number of CUs)) ≤
160

Number of pairs ≤ 4,096

Figure 3 Configuration of Cnt Ac-S Z synchronous pair M-VOLs and R-VOLs using TPC-R

Cache failure

When a cache failure occurs on the storage system, recover the cache failure, and then
resynchronize the Cnt Ac-S Z pair from TPC-R. Resynchronizing the Cnt Ac-S Z pair before recovering
the cache failure causes the resynchronization to fail. In this case, TPC-R issues a pair-deletion
command and resynchronizes the Cnt Ac-S Z pair automatically. All data in the M-VOL is recopied
to the R-VOL.

Unregistered error code for TPC-R

When using Basic HyperSwap, an unregistered error code for TPC-R might be displayed. In this
case, recover the Cnt Ac-S Z pair using the method described in the following table.

Table 9 Unregistered error code for TPC-R

Recovery procedure

Description

Operation

Error code

Remove the failure on the
cache, and then retry the Cnt
Ac-S Z pair creation operation.

The Cnt Ac-S Z pair creation failed because
it was executed when a failure occurred in
the cache.

Pair creation

0F0E

Remove the failure in the
cache, and then retry the Cnt

The Cnt Ac-S Z pair resynchronization
operation failed because it was executed

Pair
resynchronization

Ac-S Z pair resynchronization
operation.

when a failure occurred in the cache.
Although the Cnt Ac-S Z pair is deleted and
recreated (a whole copy) by the recovery
operation of TPC-R from the Cnt Ac-S Z pair
resynchronization failure, the recovery
operation fails.

24

Requirements and specifications