Pprc, bcm command comparison – HP XP P9500 Storage User Manual
Page 19
◦
PPRC Support = Yes
◦
Service SIM of Remote Copy = Not Report
•
Initial copy priority, the CFW (cache fast write) Data option, and DFW (DASD fast write) to
R-VOL option. If CESTPAIR is used to create a pair, the following values are used for these
options. Use Remote Web Console to change these options.
◦
Initial copy priority = 0
◦
CFW Data = Copy to R-VOL. If you select the only M-VOL value, the data set that is
updated by CFW in the M-VOL cannot be used in the R-VOL. To use this data set in the
R-VOL, release the pair and format the data set.
◦
CFW Data = only M-VOL can be set with a PPRC command when the Remote Copy
Function Switch is used. Contact your HP account team for more information.
◦
DFW to R-VOL = DFW not required. This setting does not affect M-VOL I/O performance.
If one side of cache is closed due to a remote system failure, the copy operation still uses
DFW. The difference between not required and required is that new pairs cannot be
established with the required option when one side of RCU cache is closed. In this case,
the Add Pair operation fails (This restriction applies only when the CU emulation type of
RCU is 3390).
PPRC, BCM command comparison
BCM and PPRC are independent functions. Do not use BCM and PPRC for the same pair operation.
The following lists the PPRC commands that correspond BCM commands.
Table 6 Corresponding PPRC, BCM commands
Support type
BCM command
Parameter
PPRC command
config
YKBLDPTH
DEVN
CESTPATH
config
PRIM
config
SEC
config
LINK
Not supported
CGROUP
Not supported
RESETHP
config
YKMAKE/YKRESYNC
DEVN
CESTPAIR
config
PRIM
config
SEC
Command (RESYNC)
MODE
Parameter (NOCOPY)
config (CopyPace)
PACE
config (ErrorLevel)
CRIT
Not supported
MSGREQ
Not supported
ONLINSEC
config
YKSUSPND
*1
DEVN
CSUSPEND
config
PRIM
config
SEC
Not supported
PRIMARY
PPRC specifications, restrictions
19