IEA491E message
When a Continuous Access Synchronous Z pair is suspended due to a failure, the MCU reports
SCI as well as unit check status and sense bytes with F/M = FB. In response to the F/M=FB sense
bytes, the IEA491E system console message is generated (if supported by the host).
shows an example of an IEA491E message.
If the host supports GDPS and the FREEZE option is enabled, the IEA494I system console message
with extended long busy (which was generated in response to the SCI) triggers the CGROUP
(FREEZE/RUN) command.
Example 2 IEA491E message
IEA491E DSLFC0,PPRC SUSPENDED, SECONDARY NOT READY, INTERVENTION_REQUIRED, (PRI)SER=0113-90797,CCA=00
(SEC)SER=0113-90217,CCA=
P9500 response characteristics to failure conditions
The P9500 supports the CGROUP command in the GDPS environment by performing PPRC
compatible actions and returning PPRC compatible messages to failure conditions.
shows the failure conditions, and
describes the response characteristics
of the P9500 to these failure conditions.
The PPRC Support=Yes option must be selected on the RCU option dialog box. If not, the host
processor generates the system console message that includes the SIM instead of the IEA494I or
IEA491E message.
Figure 17 Failure conditions
Table 39 P9500 response characteristics to failure conditions
FREEZE function
Expected messages
Continuous
Access
Failure condition
Synchronous Z
pairs
suspended?
Not activated
No IEA480, IEA491, or IEA494 messages are
displayed.
No
Failure of all channel interfaces
on the MCU
Not activated
(1) IEA480 message (SIM for physical dev.
blocked or port of phys. dev. blocked) is displayed
No
Failure of one
physical device
Failure of a
disk on the
MCU
when the next I/O is issued to any volume in the
parity group.
in a parity
group
(2) No IEA491 or IEA494 messages are
displayed.
94
Using PPRC commands for Continuous Access Synchronous Z