The CreateHrcPair command only creates the pair. You must run the StartHrcPair command
after establishing the pair to start the remote copy process.
The CreateHrcPair parameters are:

CreateHrcPair∆$Dev= M-VOL device list

,$RcuSn= Serial number list

,$RcuSsid= SSID number list

,$Rdev= R-VOL device list

[,$CopyPace= Initial copy pace list]

[,$CopyMode= Initial copy mode list]

[,$Sync= Sync level list]

[,$CTG= CT group list]

[,$Priority= Priority list]

[,$Fence= Fence level list]

[,$OptCfw= CFW flag list]

[,$OptSusDfwBlk= DFW flag list]

[,$OptErrLv= Error level list]

[,$TimeSave= Time-Saving Mode flag]

[,$Diff= Differential management measurement flag list]

[,$TimeStamp= Time stamp transfer list]

The Details for the arguments are:

M-VOL device list (numeric): L x 0x10000 + C x 0x100 + VV, where L=LDKC#, C=CU#,
VV=vol# within CU.

Serial number list (string): RCU serial number (serial number is five digits decimal 0-9). Do not
specify more than 12 RCUs.

SSID number list (numeric): RCU SSID (four digits hexadecimal).

R-VOL device list (numeric): L x 0x10000 + C x 0x100 + VV, where L=LDKC#, C=CU#,
VV=vol# within CU.
When you write M-VOL device list or R-VOL device list, you can omit LDKC# if the LDKC# is
0. For example, you can write 0x0102 when LDKC# is 0, CU# is 1, and vol# is 2.

Initial copy pace list (string): “CP_MIDDLE” = 3 tracks; “CP_FAST” = 15 tracks; default =
CP_FAST. Initial copy pace list (string): “CP_MIDDLE” = 3 tracks; “CP_FAST” = 15 tracks;
default = CP_FAST.

Initial copy mode list (string): “E” = entire volume; “N” = none; default = E.

Sync level list (string): “S0” or “Synchronous0” ; default = S0.

Priority list (numeric): Priority of initial copy operation (1 -256); default = 32.

Fence level list (string): “N” or “Never” = never; “S” or “Status” = status; “D” or “Data” =
data; default = “Never”. For async pairs you must either specify N (never) or omit this
parameter.

CFW flag list (numeric): 0 = copy CFW data to R-VOL; 1 = only M-VOL; default = 1.

DFW flag list (numeric): 0 = DFW not required; 1 = DFW required; default = 0. Must be
omitted for async pairs.

Error level list (string): To maintain interchangeability with the script made with the model
before XP12000 Disk Array/XP10000 Disk Array, this parameter has been left. Do not use
this parameter with P9500.