Intermodule Error Codes

6015

Ack Timeout - Out

The Master intermodule process attempted to
initiate a packet transmission to a Slave
intermodule process, but a timeout occurred
waiting for the Slave's acknowledge.

A, B, 1

6016

Ack Timeout - In

The Master intermodule process attempted to
initiate a packet transmission from a Slave
intermodule process, but a timeout occurred
waiting for the Slave's acknowledge.

A, B, 1

6017

Ack Invalid - Out

The Master intermodule process attempted to
initiate a packet transmission to a Slave
intermodule process, but the Slave's acknowledge
was invalid.

A, B, 1

6018

Ack Invalid - In

The Master intermodule process attempted to
initiate a packet transmission from a Slave
intermodule process, but the Slave's acknowledge
was invalid.

A, B, 1

6019

Comm Port Ack Error

The Master intermodule process, after sending a
control byte to a Slave, was waiting for an
acknowledge, but the UART detected an error
condition.

A, B, 1

6020

Command Overlap

The Master intermodule process received a
Command from the Master control process, but a
previously issued command is still being
executed.

A, B, 1

6021

Slave RTS Still Set

The Master intermodule process has received a
valid acknowledge from a Slave, but the Slave's
RTSi line has remained asserted.

A, B, 1

6022

Slave Addr Invalid

The Master intermodule process received a
CommBlock from the Master control process, but
the specified Slave address exceeds the
maximum valid range.

A, B, 1

6023

Slave Req Unknown

The Master intermodule process detected an
active SRVREQ line, but, after sequencing
through all slave addresses, determined that no
Slave had its RTSi line asserted.

A, B, 1

6024

Slave Has No Pkts

The Master intermodule process is requesting the
Slave to send a packet, but the Slave has no
packets to send.

A, B, 1

6025

Pkt ID Invalid

A, B, 1

6026

No Slaves to Flash

D, 1

6027

Master Has No Flash

D, 1

6028

Slave Unavailable

D, 1

6029

Slave Has No Flash

D, 1

6030

Slave Dev. Incompat.

D, 1

FSC