Motor process error codes (3xxx) – HP Integrity NonStop H-Series User Manual
Page 119
Error Recovery Procedures and Fault Symptom
Codes
N1525A ACL Installation and User’s Guide — 527339-003
C- 7
Motor Process Error Codes (3xxx)
Motor Process Error Codes (3xxx)
2073
Drive Config Error
Set if the Alternate Unload has not been selected.
A, 3
2074
Stow Error
A stow timeout error has occurred when
accessing a remote unit. Press Enter to Reboot
for orphan cartridge recovery.
D, #
2075
Fetch Error
During a remote fetch operation, the remote unit
returned an error.
D, #
FSC
Message
Description
ERP
3001
Picker Retries Exceeded
Remove from code.
A, B, 1, #
3002
Picker Tach Errors
TACH errors were detected during a picker
movement.
A, B, 2, 1,
#
3003
Elevator Tach Errors
TACH errors were detected during an elevator
movement.
A, B, 2, 1,
#
3004
Elevator Init Error
An elevator jam was detected during initialization.
A, B, 2, 1,
#
3006
Passthru Tach Errors
TACH errors were detected during pass-thru
elevator movement.
A, B, 4, 1,
#
3007
LTO Timeout Error
Communication with one of the LTO drives was
unsuccessful. A command was issued but status
was not returned.
A, B, 3, 1
3008
Invalid Drive State
Currently unused
A, B, 1
3009
Door Tach Errors
TACH errors were detected during a door
movement.
A, B, 15, 1
300A
Door Fault
During initialization, the door was found to be in
an improper state.
A, B, 15, 1
300B
Elev Open Tach
Open Tach detected on elevator motor.
A, B, 2, 1,
#
300C
Picker Open Tach
Open Tach detected on picker motor.
A, B, 2, 1,
#
300D
Door Open Tach
Open Tach detected on door motor.
A, B, 15, 1
300E
Drive Stow Error
A problem was encountered while trying to stow a
cartridge to a drive. Couldn't close the door.
A, B, 9, 2,
3, #
300F
Slave Init Error
The slave module could not complete the elevator
initialization. This error will occur if the unit is
configured for slave mode, but the passthrough
cover plate has not been removed from the unit.
A, B,
3010
Picker Retries Exceeded
While attempting to fetch a cartridge, the picker
was not able position properly within 16 attempts.
A, B, 2, 7,
#
FSC
Message
Description
ERP