C -12
Intermodule Error Codes
Intermodule Error Codes
5039
Invalid Unlock Code
Display message only when an invalid unlock
code is entered.
D, 5
503A
Auto Cleaning
Display message only -not an error
4
5090
Slave Command Failure
Error occurred sending a menu mode command
to a slave module.
D, 1
FSC
Message
Description
ERP
6001
Comm Port Open Error
An attempt to open the RS-232 serial
communication port used by the intermodule
processes failed.
A, B, 1
6002
Comm Port Send Error
An intermodule process was sending a packet to
a remote module, but the UART detected an error
condition during the transfer.
A, B, 1
6003
Comm Port Recv Error
An intermodule process (Master or Slave) was
receiving a packet from a remote module, but the
UART detected an error condition during the
transfer.
A, B, 1
6004
EnQ Without IDs
A, B, 1
6005
DeQ Without IDs
A, B, 1
6006
EnQ Null Pointer
A, B, 1
6007
No Free Comm Blks
A, B, 1
6010
Pkt Send Error
The intermodule process has repeatedly
attempted to send a packet to a intermodule
process, but all retries have been exhausted
before the packet could be successfully sent.
A, B, 1
6011
Pkt Receive Error
The Master intermodule process has repeatedly
attempted to receive a packet from a Slave
intermodule process, but all retries have been
exhausted before the packet could be
successfully received.
A, B, 1
6012
Status Unexpected
The Master intermodule process received a
Status packet, but no Command is currently
active.
A, B, 1
6013
Invalid Com Blk Type
The Master intermodule process received a
packet from a Slave intermodule process, but the
packet's CommBlock type was invalid.
A, B, 1
6014
Invalid Com Blk Type
The Master intermodule process received a
packet from the Command/Message queue, but
the packet's CommBlock type was invalid.
A, B, 1
FSC
Message
Description
ERP