If the HA Summary field displays Disruptive Failover Ready, click the
Synchronize Services Button and wait for the CPs to complete a
synchronization of services, so that a Non-Disruptive Failover is ready.

Once the HA Summary field displays Non-Disruptive Failover Ready a
failover can be initiated without disrupting frame traffic on the fabric.

Initiating a CP Failover

Perform the following steps to initiate a CP failover.

1. Launch the web browser.

2. Enter the IP address in the Location/Address field and press Enter.

Example:

http://123.123.123.123

Web Tools launches, displaying Switch Explorer view.

3. Click a switch in the Fabric Tree.

The Switch graphic appears.

4. Click the Hi Avail icon on the switch panel.

The HA Admin window appears as shown in

Figure 17

.

5. Verify that HA Summary field displays Non-Disruptive Failover Ready or

Disruptive Failover Ready. See “

Synchronizing Services on the CP

” on

page 89 for more information.

6. Click the Initiate Failover button. A non-disruptive failover may take a few

minutes to complete. You may lose connection to the switch for a few minutes
during the Failover. Web Tools will automatically resume the connection after
the failover.