Fabric Watch

181

Web Tools Version 3.1.x/4.1.x User Guide

Using the Threshold Configuration Tab

Use the Configuration tab to configure and view alarms as shown in the following
sections.

Configuring Boundary and Alarm Settings

1. Launch Fabric Watch (see

Launch Web Tools.

” on page 173).

2. Select the Threshold Configuration tab.

3. Select the Area Configuration sub-tab.

4. Highlight an element in the navigation tree.

You can select a whole device (such as a Switch) or an element of that device
(such as Security).

5. Select an Area (such as temperature or fan) from the Area drop-down menu.

6. Configure the Threshold Settings.

7. Configure the Alarm Settings.

8. (Optional) Check the Flash box to update the flash memory.

9. Click the Apply button.

10. Enable Alarms (see “

Enable/Disable Alarm Configurations

” on page 181).

Enable/Disable Alarm Configurations

1. Launch Fabric Watch (see

Launch Web Tools.

” on page 173).

2. Select the Threshold Configuration tab.

3. Select the Element Configuration sub-tab.

4. Select a previously configured element from the navigation tree (see

Configuring Boundary and Alarm Settings

” on page 181).

5. Select the alarm area to be enabled or disabled from the Area drop-down

menu.

6. Select the Element Configuration tab.

7. Select the alarm Element to be enabled/disabled from the Select Element

drop-down menu.

8. Select the Enable or Disable radio button.

9. Click the Apply button.