20 power, ground and no connections – AMD Geode SC3200 User Manual
Page 68
![background image](/manuals/38717/68/background.png)
68
AMD Geode™ SC3200 Processor Data Book
32581C
3.4.20
Power, Ground and No Connections
1
Signal Name
Ball No.
Type
Description
AV
SSPLL2
C16
GND
Analog PLL2 Ground Connection.
AV
SSPLL3
AK3
GND
Analog PLL3 Ground Connection.
V
PLL2
A17
PWR
3.3V PLL2 Analog Power Connection. Low noise power for PLL2 and
PLL5.
V
PLL3
AJ4
PWR
3.3V PLL3 Analog Power Connection. Low noise power for PLL3,
PLL4, and PLL6.
AV
CCUSB
D27
PWR
3.3V Analog USB Power Connection. Low noise power.
AV
SSUSB
C27
GND
Analog USB Ground Connection.
V
BAT
AL3
PWR
Battery. Provides battery back-up to the RTC and ACPI registers, when
V
SB
is lower than the minimum value (see Table 9-3 on page 352). The
ball is connected to the internal logic through a series resistor for UL pro-
tection. If battery backup is not desired, connect V
BAT
to V
SS
.
V
SB
AL5
PWR
3.3V Standby Power Supply. Provides power to the Real-Time Clock
(RTC) and ACPI circuitry while the main power supply is turned off.
V
SBL
AL6
PWR
1.8V Standby Power Supply. Provides power to the internal logic while
the main power supply is turned off. This signal requires a 0.1
μF bypass
capacitor to V
SS
. This supply must be present when V
SB
is present.
V
CORE
on page 40.
(Total of 29)
PWR
1.8V Core Processor Power Connections.
V
IO
on page 40.
(Total of 46)
PWR
3.3V I/O Power Connections.
V
SS
on page 40.
(Total of 96)
GND
Ground Connections.
NC
on page 40.
(Total of 13)
---
No Connections. These lines should be left disconnected. Connecting a
pull-up/-down resistor or to an active signal could cause unexpected
results and possible malfunctions.
1.
All power sources except V
BAT
must be connected, even if the function is not used.