beautypg.com

4 operating conditions, Table 9-3, Operating conditions – AMD Geode SC3200 User Manual

Page 352

background image

352

AMD Geode™ SC3200 Processor Data Book

Electrical Specifications

32581C

9.1.4

Operating Conditions

Table 9-3 lists the various power supplies of the SC3200 and provides the device operating conditions.

Notes:

1)

All power sources except V

BAT

must be connected,

even if the function is not used.

2)

V

SB

, and V

SBL

must be on if any other voltage is

applied. V

SB

and V

BAT

voltages can be applied sepa-

rately. See Section 9.3.15 "Power-Up Sequencing" on
page 416.

3)

The power planes of the SC3200 can be turned on or
off. For more information, see Section 6.2.9 "Power
Management Logic" on page 156.

4)

It is recommended that the voltage difference between
V

CORE

and V

SBL

be less than 0.25V, in order to reduce

leakage current. If the voltage difference exceeds
0.25V, excessive leakage current is used in gates that
are connected on the boundary between voltage
domains.

5)

It is recommended that the voltage difference between
V

IO

and V

SB

be less than 0.25V, in order to reduce

leakage current. If the voltage difference exceeds
0.25V, excessive leakage current is used in gates that
are connected on the boundary between voltage
domains.

Table 9-3. Operating Conditions

Symbol
(Note 1)

Parameter

Min

Typ

Max

Unit

Comments

T

C

Operating case temperature

0

-

85

o

C

AV

CCUSB

Analog power supply. Powers internal ana-
log circuits and some external signals (see
Table 9-4).

3.14

3.3

3.46

V

V

BAT

Battery supply voltage. Powers RTC and
ACPI when V

BAT

is greater than V

SB

(by at

least 0.5V), and some external signals (see
Table 9-4).

2.4

3.0

3.46

V

V

IO

I/O buffer power supply. Powers most of
the external signals (see Table 9-4); certain
signals within this power plane are 5V
tolerant.

3.14

3.3

3.46

V

V

CORE

Core processor and internal digital power
supply. Powers internal digital logic, includ-
ing internal frequency multipliers.

1.71

1.8

1.99

V

V

PLL2

V

PLL3

PLL. Internal Phase Locked Loops (PLL)
power supply.

3.14

3.3

3.46

V

V

SB

Standby power supply. Powers RTC and
ACPI when V

SB

is greater than V

BAT

-0.5V,

and some external signals (see Table 9-4).

3.14

3.3

3.46

V

V

SBL

Standby logic. Powers internal logic
needed to support Standby V

SB

.

V

SBL

requires a 0.1 µF bypass capacitor to

V

SS

.

1.71

1.8

1.99

V

Note 1. For V

IH

(Input High Voltage), V

IL

(Input Low Voltage), I

OH

(Output High Current), and I

OL

(Output Low Current) op-

erating conditions refer to Section 9.2 "DC Characteristics" on page 357.